Home > News

Mechanical cutting control system of glazed tile press

Dec. 30, 2020

1、 Computer display

1. Inverter is a very important part of automatic tile pressing machine, users can't operate it

2. After the host is powered on, press any number key to enter the main screen; the main screen displays length, plan, finish, progress, run, manual, and one of them can be selected through the selection key. The size of the item can be set with the number key. C and CE are all reset keys. The length is the specification length of the rolled plate, and the unit is mm. The planned value is the number of the plate to be pressed, The finished value is the rolled quantity, and the progress is the rolled length in the rolling process. When the progress value is equal to the length value, the system will stop, cut automatically, and add one to the finished quantity automatically

3. The user needs to set the length value and the planned number first, and then through the [Select] key, select the operation option, and then press the [OK] key to realize the automatic operation. When the completed number is less than the planned number, the system starts to run until they are equal; when the completed number is greater than or equal to the planned number, the system starts to run, and only one plate is rolled and automatically stops after cutting. Press the [reset] key to stop

2、 Control cabinet panel of glazed tile press

1. The forward and backward operation of the main engine is controlled by the frequency converter, and its speed can be controlled by the high / low speed switch on the panel. In the automatic operation, the speed switch must be placed at the high speed

2. The oil pump switch is used to control the start and stop of the oil pump. Before the operation, please turn on the oil pump to provide pressure for the hydraulic system. After the operation of the oil pump, pay attention to whether the running direction of the oil pump is consistent with the direction of the arrow. If not, please replace any two of the three-phase electricity in the oil pump motor

3. The down cut and return buttons are used to control the operation of the cutter. If the down cut and return buttons are invalid, it should be considered whether the oil level of the hydraulic oil tank is too low, and the hydraulic oil should be added to the empty tank. In addition, in the process of down cut and return of the cutter, the operation will stop automatically when encountering the front limit switch


Contact Us
Follow Us